<Error>
<ErrorNumber>38192</ErrorNumber>
<ErrorFamily>Main Plot Control</ErrorFamily>
<ErrorMessage>
MPC: The &lt;Plate identifier&gt; is positioned &lt;Error distance&gt; mm too close to the &lt;Error direction&gt; side
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_400_Fiber_Head_Machine</Text></ListItem>
<ListItem><Text>Lotem_800_Fiber_Head_Machine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The plate is positioned incorrectly along the drum.  This could result in either
failure to find the edge, or the plate not sitting on the required registration
pins.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Ensure that the plate is loaded in the correct position along the drum for the
particular plate dimensions.  Ensure that the plate dimensions specified in the
job match the physical plate dimensions.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The head is over the plate at the minimum edge search position
</Cause>
<Cause>
No edge has been detected up to the maximum edge search position
</Cause>
<Cause>
The plate is not positioned over the correct registration pins
</Cause>
<Cause>
The plate dimensions specified in the job do not match the physical plate
dimensions
</Cause>
<Parameter>
Plate identifier
This is either "home", "away" or nothing, depending on how many plates are loaded
and which plate is wrongly positioned.
</Parameter>
<Parameter>
Error distance
This is how far away from the ideal position the plate is actually positioned.
</Parameter>
<Parameter>
Error direction
This indicates which direction the position error is in, either "home" or "away".
</Parameter>
<LastModified>
13-Jun-2006
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:11 2008 PST
</Updated>
<Links>
</Links>
</Error>